Sump Pump Service: What The Written Report Should Show

Request a sump-pump service report that separates primary, backup and alarm checks, observed results and untested limitations.

Published November 9, 2026 · LocalServ.Pro

A service note that says “pump tested” leaves an important question unanswered: which part of the installed system was tested? Ask the service company to identify the primary pump, any backup arrangement and any alarm separately. A useful report connects each component with the work actually performed, the observed result and the limits of that visit.

Before You Begin

This is a record to request from a qualified service provider. It does not tell you to add water to a pit, interrupt power, open a controller or handle a battery. Arrange service from a safe location and keep clear of wet electrical equipment.

Identify The Equipment And Instructions

Give the company any existing installation record, prior invoice and safely available model information. Ask it to complete missing identifiers during the visit. Similar-looking pumps or controllers can have different instructions; do not substitute an online manual because the photograph looks familiar.

As a concrete example, Zoeller’s FM3315 instructions, revision 0725, cover the Aquanot Key 507/73 package: a Model 507 battery backup with an M73 primary pump. The document describes separate backup operation and controller/alarm indications. It assigns electrical installation and servicing to a qualified licensed electrician and calls for an authorized service station for repair and service of that DC backup system. Those instructions do not establish the requirements for another make or model. Manufacturer instructions

Request This Component Record

Ask the provider to fill one row per component. “Not installed,” “not tested” and “test incomplete” should remain distinct answers.

Swipe or scroll sideways to compare every column. Keyboard users can focus the table area and use the arrow keys.

Request This Component Record — Worksheet
Pump IdentifierProfessional Test PerformedObserved ResultPower/Backup ScopeAlarm ScopeUntested LimitationNext Service Contact
Primary pump: manufacturer/model recorded by providerName the test and applicable instructionsRecord what happened during the visitState which power arrangement was assessedState whether an alarm was part of this testList anything that prevented completionPerson or company responsible for the next action
Backup pump/controller, if installedDescribe the separate test, or state that none was performedRecord the result separately from the primary pumpIdentify what the backup assessment includedRecord the indication or notification actually checkedIdentify any battery, controller or other check left openContact and agreed follow-up date
Separate alarm, if installedState how the provider assessed itDistinguish a local indication from a received remote notificationRecord relevant limitsName the receiving device/person only with permissionState if remote delivery was not verifiedWho resolves the missing verification?

Illustrative report review: the invoice identifies the primary pump and records a successful operating check, but says nothing about the backup. Ask whether backup work was outside the booking or was performed and omitted from the report. Do not fill the blank by assuming it passed.

Keep The Result Within Its Limits

A result observed during one visit does not establish performance in every future storm or outage. Ask the provider to explain what remains uncertain, including anything outside the agreed equipment assessment. A pump-service record also does not establish that a discharge connection is locally permitted. Keep utility or local-authority approvals with the property’s separate drainage records.

Before closing the visit, identify who will address each open item and how you will receive confirmation. Keep a contact plan available if the owner cannot be reached. Ready PA’s emergency-planning guidance recommends identifying local and out-of-area contacts; that is useful preparation, not a sump-system performance standard. Ready PA planning guidance

Does an audible alarm prove a phone notification arrived? Record them separately. Ask for the actual outcome of each agreed check rather than treating one as evidence of the other.

Can a blank row mean the component passed? Ask the author of the report. A missing result is an unresolved record, not a test outcome.

Use LocalServ’s basement-waterproofing guide for a wider scope discussion and the quote worksheet for service proposals. LocalServ does not test equipment or certify flood protection.

Sources And Local Resources

Sources checked November 9, 2026. Confirm current requirements with the authority responsible for your property.